South Korea Adds New Water Sources for Renewable Heat

Read the analysis
Standing water among concrete walls at a disused wastewater treatment site
Standing water at a disused wastewater treatment site in Switzerland. scoob_switzerland / Pixabay · https://pixabay.com/service/license-summary/

South Korea’s cabinet approved a change that will allow more water sources to qualify as renewable heat. The new categories include discharged groundwater, wastewater, and industrial water, opening up potential sources closer to buildings and factories.

South Korea plans to recognize seven additional categories of water for renewable heating and cooling. The environment ministry said the cabinet approved the decree amendment on November 10 and expected it to take effect on November 17. A separate ministry notice is intended to designate the sources under the revised rule. Among them are discharged groundwater, municipal and industrial wastewater, and industrial water. Looking for those streams near the places that need heat can change where developers start evaluating a project.

A Heat Pump Moves Heat Already in the Water

A water-source heat pump passes heat from water to a refrigerant through a heat exchanger. The compressor raises the refrigerant’s temperature so it can transfer heat to a building or a process at the required temperature. The two fluids remain on their own sides of the exchanger. That separation makes it possible, in principle, to recover heat from water that would be unsuitable for direct use in a building’s pipes.

The electricity needed to run the compressor depends in part on how far the equipment must raise the temperature. A stream that remains relatively warm in winter can require less of that lift for a given delivery temperature. The heat delivered by the equipment still depends on the source temperature and the needs of the building. A low-temperature floor heating system and a process that requires hotter water may make different demands on the same source. One should not use the measured performance of the first to predict the performance of the second.

Proximity Makes Some Streams Worth a Second Look

The change creates a way to recognize additional water categories with relatively stable temperature and flow. A site that is far from a large body of water may still sit beside a stream that is regularly collected or discharged. Groundwater already being pumped from an underground structure is one example of where the search can begin. At an industrial site, a stream already moving through the property can put a potential source close to the process that needs heat. The shorter the route, the less pipe, pumping and coordination may be needed to link the two.

Proximity means little if flow disappears at the wrong time. Designers need to compare the hours when the source is available with the hours when heating or cooling is highest. A process whose output falls at weekends may suit a neighboring factory with a matching schedule and be a poor fit for another customer that needs continuous heat. Water temperature and flow need to be observed through seasons and operating shifts, rather than measured once and assumed to hold.

The Water Service Sets the Operating Limits

A heat recovery proposal also has to work for the people who run the water system. A wastewater stream can foul an exchanger, reducing the transfer of heat and creating a cleaning requirement. Access, bypass arrangements and room to isolate equipment can affect whether maintenance disrupts the water service. Where water is discharged or returned to another process, a project must establish what temperature and flow that receiving system can accept.

The new definition resolves one screening question: whether these categories can count as renewable water-source heat. It does not answer what a particular building will pay for heat or how much electricity its equipment will consume. A sensible first comparison measures the water stream and the heat demand together. That reveals whether the nearby source should stay on the drawing board before anyone commits to a pipe route or a heat pump.

Take-Out

The change gives developers a reason to screen nearby water streams before looking farther afield. What counts in practice is the heat they can deliver through the year, after allowing for electricity, maintenance, and the water system’s own needs.

Questions and answers

What readers should know

What did the cabinet approve?
An amendment to the renewable energy decree that enables additional water categories to be designated.
How many new categories are planned?
The ministry identified seven. They include discharged groundwater, wastewater, and industrial water.
When was the change expected to take effect?
The ministry expected the amended decree to take effect on November 17, following the November 10 cabinet decision.
Does wastewater circulate through the building?
A heat exchanger can transfer energy while keeping the source water and building circuit separate.
What should developers measure first?
Source flow and temperature across operating conditions, alongside the timing and temperature of the heat demand.